IMPORTANT : A licensed NEXUS Certified Electrician with knowledge and understanding of electrical systems and electrical safety should complete the electrical installation.
STEP 1: TURN OFF ELECTRICITY
The electricity to the circuit must be shut off during installation for safety and to ensure that wires are not short-circuited which will cause damage to the NEXUS-BLIND.
STEP 2: WIRE THE NEXUS-BLIND
If the NEXUS-BLIND is going to be operated using one switch the external switch must connect ST and COM., as below
STEP 3: CHANGE THE PARAMETER
3.1 Click on the spanner of the NEXUS-BLIND device to open the device settings.
3.2 Select the DEVICE OPTIONS tab, then click ADD CONFIGURATION SETTINGS
Enter the parameter details (see opposite) then close the settings and click SAVE
Parameter: 8
Data Type: 1 byte dec (1d)
Default value: 0 (3 button switching) Default Value
Possible Value: 1 (single button switching)